Technical Data
Product Accessories
Warning
Installation and adjustment must be carried out according to the Installation Manual.Carelessness in installation and adjustment will lead to such accidents as fire.electric shocks or fall off.
During the installation never allow the pedestrians to pass through the automatic door or approach the work site. Because any tools or parts falling off during the installation will cause injury to the pedestrians.
Never remodel the parts, otherwise fire, electric shocks or fall will occur.
Never use the power beyond the stipulated voltage or frequency, otherwise fire or electric shocks will occur.
The sensor should be set and adjusted to make sure that the opening area of the door will fully fall into the range of sensor detection without any blind area. If the detecting range is too small or having blind area, the pedestrians will be collided or squeezed by the door, causing injury.
Caution
Never use the door in a place subject to dampness, vibration or corrosive gas, otherwise it will cause such accidents as fire , electric shocks or fall.
Make sure that a space of over 30mm should be available when the door is opened, otherwise your fingers may be squeezed by the door leaf and upright column , causing injury.
Never cut off power when the door is in operation , otherwise it will cause injury of the pedestrians
Please use sticker on door leaves . If not , it will cause injury to the passer-by who has lost sight of the door Ieaf.
Never install an electric device with a capacity of > DC24V 300mA to the controller ,otherwise it will cause fire.
Other Precautions
Never use a door leaf that exceeds the specified weight , otherwise it will cause failure.
For selection of batteries
Please use them after charging for 24 hours.
The service life of batteries lasts for 3-5 years at an ambient temperature of 0℃-40℃.Excessive temperature will shorten the service life of batteries.
If after charging 24 hours the battery stil doesn't work , it shows the service life has expired, Replace it immediately.
Check batteries each half year.
For selection of electronic lock
Never use it in an environment excess an ambient temperature of 0℃-40℃ , otherwise it will cause malfunction.
Using our brand electronic lock , and special installing brackets . If not using our lock,please make sure the quality of lock , or the bad electronic lock will damage.
Product Features
Microprocessor control technology and advanced mechanical manufacture.
Self-learning when power on , this function is selectable by user.
Digital screen , easy and exact to adjust working data.
Brushless DC motor , long working life and low noise ( less then 40dp)
Anti-clamp when close and open.
Function terminals for electronic lock , access keypad , function keypad , function remote and so on.
Special terminals for anti-clamp side sensor , more safety.
Square motor for narrow door entrance
Sectional View of Track And Cover
Track’s Cutting And Installation
Installation
The track is installed at a height of DH+23mm from the ground(Based on the bottom of the track)
(1)Drill holes in aluminum track
(2)Fix one end off aluminum track,check the level by gradienter,then fix another end of track
(3)Fix the aluminum track to steel structure firmly
Caution
(1)The track must be level
(2)The height of movable door leaf is DH
(3)The clearance height over the track shoule be more than 50mm
Installation of Motor
Installation of Controller
Installation of Idler Pulley
Installation of Stopper
Installation of Hanger
Caution: In installation the pulley center of the hanger should be in full parallel with the door leaf. If not,the service life of the pulley will be shortened!
Installation And Adjustment of Door Leaf
If the door leaf can t be installed horizontally, it can be adjusted by the adjusting bolt.
If the door leaf is hard to move, the following items should be checked to solve the problem:
1.The hanger is mounted vertically on the leaf.
2.Any friction between the floor guide and the leaf bottom of door leaf.
3.Any friction between the door leaf and frame.
4.Any friction between the hanger and anti-drop device, any friction between the hanger and the rail.
1 . Remove the bolt and take off the belt fastening part from the belt connector part.
2 . Cut the belt according to the belt cutting table.
Caution : Cut the belt at the center of the valley bottom.
3 . Both ends of the belt are put into the fastening part from the center of the fastening part.
Caution : Never have the belt twisted in installation.
4 . Fix the fastening part to the belt connector part.
Caution : the direction of the belt fastener.
5 . Fix the belt connector part to hanger.
Caution : Do tighten the bolts firmly.
Remove the bolt and take off the belt fastening part from the belt connector part.
Cut the belt according to the belt cutting table.
Caution : Cut the belt at the center of the valley bottom.
Both ends of the belt are put into the fastening part from the center of the fastening part.
Caution : Never have the belt twisted in installation.
Fix the fastening part to the belt connector part.
Loosen the four fastening bolts.
Turn the tension adjusting bolt counter clockwise to make sure the fastening bolt at the max left position.
Pull the idler pulley to the left to keep the belt tightened and fasten the four pressure plate bolts.
Turn the tension adjusting bolt clockwise so that the tension plate will be moved to the left and the belt tension increased gradually.
Adjusting the belt tension to tighten belt suitably .
Installation of Door Leaf Guider
Installation of Electronic Lock
Connect the electronic lock with the E-lock installing bracket.
Inset the E-lock installing bracket to the rail.
Connect the magnet holder with the hanger .
Adjust the position of the electronic lock to make the distance between E-lock and magnet holder max 5mm , then tighten the bolt.
Caution : The position of hanger is the position when door closed
Terminal Details of Controller
Connection of Remote
Connection of UPS And Electronic Lock
Connection of Sensor
Connection of Motor,Controller And Power Switch
Connection of Inter-lock
Adjustment of Open And Close Parameters
TEST:One press finishes on open action and can be used for adjusting each parameter in installation.
DRP:The lamp is always on after operation
A:Single-leaf door,Switch left is for open to the leaf and switch right for open to the right
B:Left align when electric lock is use, make sure unlocking before before opening,Right switch:normal state
C:Left:Door keep open in battery mode. Right:Door open and close automatically in battery mode
D:Turning counterclockwise will reduce open speed while clockwise will increase speed
E:Turning counterclockwise will reduce open speed while clockwise will increase speed
Travel distance setting
Power off and restart the system, door will close slowly, controller indicator 1 second on,1 second off. When controller receive open signal, Door will open and close one time to setting travel distance. After setting, indicator 3 seconds on 3 seconds off, door will in normal mode.
Regulation steps : open and close the door manually for several times to confirm the door can be open and close freely.
(2)Unlocking delay switch is set. When electric lock is connected externally, align left,otherwise switch right without exception
(3)The door is pushed to the close position and set initially
(4)After switching on power , the door is opened slowly and closed after meeting with the stopper the door is under initialization. press the test button of the controller and regulate the buffer speed while opening and closing the door.
(5)When the door is closed,close speed and close slow down distance can be set as required.
(6)Press the test button and set open speed and open slow down distance.
Press the test button of the controller,when opening the door, open speed and open slow down distance should be set as required.
Caution:setting should be conducted after confirming that no pedestrian is around the door,otherwise injury may be caused.
Caution:open slow down distance must be set to over 5cm,or will cause damage to the door
(7)Regulate open time for the door
Caution:Never setting when door is opening or closing.Setting slowly as turning the button too fast will cause damage to the door or injury to personnel.
Installation Process
Trouble Shooting
Technical Data
Product Accessories
Warning
Installation and adjustment must be carried out according to the Installation Manual.Carelessness in installation and adjustment will lead to such accidents as fire.electric shocks or fall off.
During the installation never allow the pedestrians to pass through the automatic door or approach the work site. Because any tools or parts falling off during the installation will cause injury to the pedestrians.
Never remodel the parts, otherwise fire, electric shocks or fall will occur.
Never use the power beyond the stipulated voltage or frequency, otherwise fire or electric shocks will occur.
The sensor should be set and adjusted to make sure that the opening area of the door will fully fall into the range of sensor detection without any blind area. If the detecting range is too small or having blind area, the pedestrians will be collided or squeezed by the door, causing injury.
Caution
Never use the door in a place subject to dampness, vibration or corrosive gas, otherwise it will cause such accidents as fire , electric shocks or fall.
Make sure that a space of over 30mm should be available when the door is opened, otherwise your fingers may be squeezed by the door leaf and upright column , causing injury.
Never cut off power when the door is in operation , otherwise it will cause injury of the pedestrians
Please use sticker on door leaves . If not , it will cause injury to the passer-by who has lost sight of the door Ieaf.
Never install an electric device with a capacity of > DC24V 300mA to the controller ,otherwise it will cause fire.
Other Precautions
Never use a door leaf that exceeds the specified weight , otherwise it will cause failure.
For selection of batteries
Please use them after charging for 24 hours.
The service life of batteries lasts for 3-5 years at an ambient temperature of 0℃-40℃.Excessive temperature will shorten the service life of batteries.
If after charging 24 hours the battery stil doesn't work , it shows the service life has expired, Replace it immediately.
Check batteries each half year.
For selection of electronic lock
Never use it in an environment excess an ambient temperature of 0℃-40℃ , otherwise it will cause malfunction.
Using our brand electronic lock , and special installing brackets . If not using our lock,please make sure the quality of lock , or the bad electronic lock will damage.
Product Features
Microprocessor control technology and advanced mechanical manufacture.
Self-learning when power on , this function is selectable by user.
Digital screen , easy and exact to adjust working data.
Brushless DC motor , long working life and low noise ( less then 40dp)
Anti-clamp when close and open.
Function terminals for electronic lock , access keypad , function keypad , function remote and so on.
Special terminals for anti-clamp side sensor , more safety.
Square motor for narrow door entrance
Sectional View of Track And Cover
Track’s Cutting And Installation
Installation
The track is installed at a height of DH+23mm from the ground(Based on the bottom of the track)
(1)Drill holes in aluminum track
(2)Fix one end off aluminum track,check the level by gradienter,then fix another end of track
(3)Fix the aluminum track to steel structure firmly
Caution
(1)The track must be level
(2)The height of movable door leaf is DH
(3)The clearance height over the track shoule be more than 50mm
Installation of Motor
Installation of Controller
Installation of Idler Pulley
Installation of Stopper
Installation of Hanger
Caution: In installation the pulley center of the hanger should be in full parallel with the door leaf. If not,the service life of the pulley will be shortened!
Installation And Adjustment of Door Leaf
If the door leaf can t be installed horizontally, it can be adjusted by the adjusting bolt.
If the door leaf is hard to move, the following items should be checked to solve the problem:
1.The hanger is mounted vertically on the leaf.
2.Any friction between the floor guide and the leaf bottom of door leaf.
3.Any friction between the door leaf and frame.
4.Any friction between the hanger and anti-drop device, any friction between the hanger and the rail.
1 . Remove the bolt and take off the belt fastening part from the belt connector part.
2 . Cut the belt according to the belt cutting table.
Caution : Cut the belt at the center of the valley bottom.
3 . Both ends of the belt are put into the fastening part from the center of the fastening part.
Caution : Never have the belt twisted in installation.
4 . Fix the fastening part to the belt connector part.
Caution : the direction of the belt fastener.
5 . Fix the belt connector part to hanger.
Caution : Do tighten the bolts firmly.
Remove the bolt and take off the belt fastening part from the belt connector part.
Cut the belt according to the belt cutting table.
Caution : Cut the belt at the center of the valley bottom.
Both ends of the belt are put into the fastening part from the center of the fastening part.
Caution : Never have the belt twisted in installation.
Fix the fastening part to the belt connector part.
Loosen the four fastening bolts.
Turn the tension adjusting bolt counter clockwise to make sure the fastening bolt at the max left position.
Pull the idler pulley to the left to keep the belt tightened and fasten the four pressure plate bolts.
Turn the tension adjusting bolt clockwise so that the tension plate will be moved to the left and the belt tension increased gradually.
Adjusting the belt tension to tighten belt suitably .
Installation of Door Leaf Guider
Installation of Electronic Lock
Connect the electronic lock with the E-lock installing bracket.
Inset the E-lock installing bracket to the rail.
Connect the magnet holder with the hanger .
Adjust the position of the electronic lock to make the distance between E-lock and magnet holder max 5mm , then tighten the bolt.
Caution : The position of hanger is the position when door closed
Terminal Details of Controller
Connection of Remote
Connection of UPS And Electronic Lock
Connection of Sensor
Connection of Motor,Controller And Power Switch
Connection of Inter-lock
Adjustment of Open And Close Parameters
TEST:One press finishes on open action and can be used for adjusting each parameter in installation.
DRP:The lamp is always on after operation
A:Single-leaf door,Switch left is for open to the leaf and switch right for open to the right
B:Left align when electric lock is use, make sure unlocking before before opening,Right switch:normal state
C:Left:Door keep open in battery mode. Right:Door open and close automatically in battery mode
D:Turning counterclockwise will reduce open speed while clockwise will increase speed
E:Turning counterclockwise will reduce open speed while clockwise will increase speed
Travel distance setting
Power off and restart the system, door will close slowly, controller indicator 1 second on,1 second off. When controller receive open signal, Door will open and close one time to setting travel distance. After setting, indicator 3 seconds on 3 seconds off, door will in normal mode.
Regulation steps : open and close the door manually for several times to confirm the door can be open and close freely.
(2)Unlocking delay switch is set. When electric lock is connected externally, align left,otherwise switch right without exception
(3)The door is pushed to the close position and set initially
(4)After switching on power , the door is opened slowly and closed after meeting with the stopper the door is under initialization. press the test button of the controller and regulate the buffer speed while opening and closing the door.
(5)When the door is closed,close speed and close slow down distance can be set as required.
(6)Press the test button and set open speed and open slow down distance.
Press the test button of the controller,when opening the door, open speed and open slow down distance should be set as required.
Caution:setting should be conducted after confirming that no pedestrian is around the door,otherwise injury may be caused.
Caution:open slow down distance must be set to over 5cm,or will cause damage to the door
(7)Regulate open time for the door
Caution:Never setting when door is opening or closing.Setting slowly as turning the button too fast will cause damage to the door or injury to personnel.
Installation Process
Trouble Shooting